A switch that received the earlier GS1900 security update may still have a LAN-reachable command-execution flaw. Zyxel’s November 3 advisory identifies a new out-of-bounds write in the CGI program of ten GS1900 models. An unauthenticated attacker on the local network could send a crafted HTTP request and potentially execute operating-system commands on the switch.

The new identifier is CVE-2026-107441. Zyxel lists each model’s 2.90(... .2)C0 firmware and earlier as affected and a matching .3 build as its patch. That includes switches whose owners updated after the earlier GS1900 CGI overflow. Check the running build again before marking those devices complete.

The CGI path starts on LAN

The affected CGI program processes HTTP requests in GS1900 firmware. An out-of-bounds write means the program can write past the memory allocated for an operation; Zyxel says a crafted request from a LAN-based, unauthenticated attacker could lead to OS-command execution. The Zyxel-assigned CVE record classifies the weakness as CWE-787 and scores it 8.8 under CVSS v3.1, with adjacent-network access and no privileges or user interaction. Adjacent access is the key condition for checking which management networks can reach these switches.

The earlier CISA exploitation entry applies to CVE-2026-7273, a separate flaw. Keep that classification attached to the earlier flaw. Prioritize the .3 patch for CVE-2026-107441 using the affected-firmware table and LAN access condition.

Match each switch to its patch

Zyxel says, “on-market products not listed in the table remain unaffected.” For the listed models, compare the specific model and running firmware branch; the letter groups in parentheses differ by model. The table retains Zyxel’s affected cutoffs and first listed patches.

GS1900 modelAffected throughListed patch
GS1900-82.90(AAHH.2)C02.90(AAHH.3)C0
GS1900-8HP2.90(AAHI.2)C02.90(AAHI.3)C0
GS1900-10HP2.90(AAZI.2)C02.90(AAZI.3)C0
GS1900-162.90(AAHJ.2)C02.90(AAHJ.3)C0
GS1900-242.90(AAHL.2)C02.90(AAHL.3)C0
GS1900-24E2.90(AAHK.2)C02.90(AAHK.3)C0
GS1900-24EP2.90(ABTO.2)C02.90(ABTO.3)C0
GS1900-24HPv22.90(ABTP.2)C02.90(ABTP.3)C0
GS1900-482.90(AAHN.2)C02.90(AAHN.3)C0
GS1900-48HPv22.90(ABTQ.2)C02.90(ABTQ.3)C0

The vendor’s affected table is model-specific. In particular, the GS1900-24HPv2 patch uses ABTP; the GS1900-48HPv2 patch uses ABTQ. A fleet search for 2.90 alone will miss that distinction.

Patch firmware and narrow management access

Identify GS1900 models in the switch inventory, read the running firmware from each device’s management interface, and map it to the corresponding row above. Install Zyxel’s listed .3 patch on affected devices. As a second layer, permit access to switch web management only from the designated admin network or jump hosts; the attack Zyxel describes requires a LAN path to the CGI program.

After updating, read the running version again. For a GS1900-24EP, for example, the expected listed patch is 2.90(ABTO.3)C0, while 2.90(ABTO.2)C0 is affected. From a regular user segment, test whether the switch’s management interface is reachable using your normal authorized access check; the expected result is access from the admin path and no access from that user segment. A successful firmware upload without a matching running version is unfinished work.